Thermal Automotive Circuit Breaker-Manual Reset

 

Application:

Type 1610 - Compact and convenient.
Miniaturised thermal type 1610 protects loads and electrical systems in passenger cars and commercial vehicles.
Fully interchangeable with blade type fuses, it brings the advantages of circuit breaker protection and reset ability to cost critical applications.
Type 1610 is also available with a colour coded manual release button or as an auto reset version.

 

Description:
Miniaturised single pole press-to-reset cycling trip free thermal circuit breaker designed for automotive fuse block installation.
Extends the benefits of circuit breaker performance and convenience to applications which are cost critical. Colour-coded housing caps or manual
release buttons available.

 

Electrical Products:

Electrical Main Page

Automotive Relays
Thermal Automotive CB

Specifications:
Voltage rating
1610-92: DC 12 V 1610-21/1610-H2: DC 32 V
Current ratings 5...30 A
Service short-circuit breaking capacity 300 operations at ≤ 50 A
Reset period for 1610-92 (at 23 °C) ≤ 15 s
Ambient temperature -40...+85 °C (-40...+185 °F)
Degree of protection operating area IP30 (-21/-H2)
(IEC 60529/DIN 40050) operating area IP54 (-92)
terminal area IP00
Ultimate short-circuit breaking capacity ≥ 3 break operations at 150 A, or ≥ 1 break operation at 2,000 A
Vibration 10 g (57-500 Hz) ± 0.38 mm (10-57 Hz) (with mounting socket 12) to IEC 60068-2-6, test Fc 10
frequency cycles/axis
Shock 50 g (11 ms) (with mounting socket 12) to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH, to IEC 60068-2-3, test Ca
Mass approx. 5 g
Dimensions: 20 w x 30 h x 6 thickness (general)
Lead free / RoHS compliant